Ia4100, Administrator guide, Programming commands (continued) – Code Blue IA4100 SINGLE BUTTON ANALOG SPEAKERPHONE User Manual

Page 18

Advertising
background image

Code Blue

259 Hedcor Street

Holland, MI 49423 USA

800.205.7186

www.codeblue.com

GU-139-J

page 18 of 29

IA4100

Administrator Guide

Programming Commands (continued)

Programming Outputs

Command

Explanation

Format

Default

11

Auxiliary output 1

11<active time>#

91

12

Auxiliary output 2

12<active time>#

01

13

Auxiliary output 3

13<active time>#

01

NOTES: Active Time Values

00 = disabled

01 - 60 = 1 to 60 seconds

61 - 90 = 1 minute to 30 minutes

91 = until the end of the call

92 = until trigger on input 2

Recording Messages

Call the extension or phone number of CB Unit, after the RFA tone:

Programming Recordings

Command

Explanation

Format

12583#

programming mode

21

Message recording #1

21<record message>#

22

Message recording #2

22<record message>#

23

Message recording #3

23<record message>#

24

Message recording #4

24<record message>#

25

Message recording #5

25<record message>#

26

Message recording #6

26<record message>#

27

Message recording #7

27<record message>#

28

Message recording #8

28<record message>#

29

Message recording #9

29<record message>#

Ý

#

hang up and exit programming

NOTES:

RECORDING STEPS

1. Enter Command 21-29 followed by the # key

2. Wait for the beep

3. Recite your message

4. Enter # to confirm completion

5. The message will be played back for approval

6. Repeat steps 1-4 if your message is not ac

ceptable

7. Enter the # key to terminate playback (21-29

Programming Mode only).

Maximum message length is 30 seconds.

To listen to a recorded message, dial ÝÝ <Command 21-29>#

For example: To listen to recording number 4 (Command 24): ÝÝ 24#

Message volume level can be changed with programming Command 67.

(Continued on next page)

Advertising