Toolvox® x3, Administrator guide – Code Blue TOOLVOX X3 User Manual
Page 42

Code Blue
•
259 Hedcor Street
•
Holland, MI 49423 USA
•
800.205.7186
•
www.codeblue.com
GU-154-F
page 42 of 132
ToolVox® X3
Administrator Guide
Buttons and Inputs
Button 1 – this is the Red button on your CB phone. By default it will try numbers in memory slots
1,2, and 3 from above. It will also play recording 1 from above and activate Outputs 1 and 3 which
are normally open contacts. The Call Cycle count is set for 2 by default, so for example if you set
Phone Numbers as 11 it would call Phone Number in memory slot 1 Four times if it encountered a
busy signal.
Button 2 – this is the Black button on your CB phone. Choose 0 as the phone number if your CB
phone has a key pad. This will provide dial tone when the black button is pushed so the keypad can
be used. If there is no key pad present then you can enter a Phone Number slot to have Button 2
place a call.
Button 3,4 – If you have a CB phone with a 3rd and 4th button you can program them here.
Input #1,#2 – select which button you want the input to mimic
Loss of AC Power – Enter the phone number memory slot 1-9 and outputs that you want the unit to
dial should there be a loss of AC power. Enter the recordings 1-9 that the unit should play when the
call is answered.
Low Battery - Enter the phone number memory slot 1-9 and outputs that you want the unit to dial
should there be a low battery condition (less than 11.7 VDC). Enter the recordings 1-9 that the unit
should play when the call is answered.
AMP SPKR Fault - Enter the phone number memory slot 1-9 and outputs that you want the unit to
dial should there be an AMP/PAS fault. Enter the recordings 1-9 that the unit should play when the
call is answered.
Call Properties
Wait For Dial Tone – 00=ring down/Hot line, 01 to 99 =1-99 seconds. If dial tone is not detected in
this time the phone will hang up.
Call Progress Detection Delay – 1 to 99 is 1-99 seconds. The time that the phone will wait to hear
progress tones after dialing.