<1> Asynchronous

In-

Band Rate

0 =150, 1 = 300, 2 = 600, 3 = 1200, 4 = 2400, 5= 4800,
6 = 9600, 7 = 19200, 8 = 38400, 9 = 57600, 10 =
115200

<1> FSK

Communications

Select

0 = None, 1 = Codan, 2 = TerraSat, 3 = Amplus

<1>

FSK Test Type

0 = None, 1 = Loopback, 2 = Cycle TX Enable, 3 =
Codan Pass thru, 4 = TerraSat pass thru, 5 = Amplus
Pass thru, 6 = Query for address

<2> BUC

Address

<1>

BUC Output Enable

0 = Disabled, 1 = Enabled

<1>

Minor Alarm Relay
Usage

0 = undefined, 1= IBS Usage, 2 = IBS & Minor Alarms,
3 = IBS, Minor Alarms and Major Alarms

<1>

Ethernet QOS Type

0 = Normal, 1 = Port based

<1> Ethernet

QOS

QUEUE

0 = Fair Weighted, 1 = Strict Priority

<1> EBEM

overhead

channel rate

0 = Off, 1 = 8K, 2 = 16K, 3 = 24K, 4 = 32K, 5 = 40K, 6
= 48K, 7 = 56K, 8 = 64K

<1> EBEM

embedded

channel

0 = Off, 1 = On

<1>

EBEM ITA

0 = Disabled, 1 = Enabled

<1>

EBEM encryption

0 = Disabled, 1 = Enabled

<4>

EBEM Ethernet rate

4800 to 52000000

<1>

Ethernet HDLC

0= Radyne, 1 = Comtech, 2 = Managed 570


Opcode: <2602h>

Command a Modulator’s Frequency

Command Data (4 Bytes)

<4>

Frequency

Selects the IF Frequency in Hz, IF Range = 50 MHz to
180 MHz, L-Band Range = 950 MHz to 2050 MHz

This command also turns the carrier off to protect
the satellite.


Opcode: <2603h>

Command a Modulator’s Strap Code

Command Data (2 Bytes)

<2>

Strap Code

Binary value

This command also turns the carrier off to protect
the satellite.


Opcode: <2604h>

Command a Modulator’s Data Rate