5 common equipment status, 6 interface transmit side status, 7 interface receive side status – Comtech EF Data SDM-309B User Manual
Page 196

SDM-309B Satellite Modem
Remote Control
MN/U-SDM309B Rev. #
B-B–19
SYN_xxx”cr”
Synthesizer lock (OK/FLT)
ICH_xxx”cr”
I-channel (OK/FLT)
QCH_xxx”cr”
Q-channel (OK/FLT)
BCLK_xxx”cr”
bit clock (OK/FLT)
BERT_xxx”cr”
BER threshold (OK/FLT)
RSL_-nn.ndBm”cr”
Receive Signal Level (level or No Data)
CSV_snnnnn”cr”
Current Sweep Value
SFLT_xx”cr””lf”]
Number of stored faults logged (0 to 10)
5.5 Common Equipment Status
The common equipment status command causes a block of data to be returned which
indicates the status of the common equipment.
Command:
<add/CES_”cr”
Response:
>add/CES_”cr”
M&C_xxx”cr
Monitor & Control Module (OK/FLT)
INT_xxx”cr”
Data Interface Module (OK/FLT)
BAT_xxx”cr”
battery (OK/FLT)
PS1_xxx”cr”
+5 volt power supply (OK/FLT)
PS2_xxx”cr”
+12 volt power supply (OK/FLT)
PS3_xxx”cr”
-12 volt power supply (OK/FLT)
MODE_xxxxxx”cr”
Mode (LOCAL or REMOTE)
SW_x.xxx”cr”
Software Version
SFLT_xx”cr””lf”]
Number of stored faults logged (0 to 10)
5.6 Interface Transmit Side Status
Command:
<add/ITXS_”cr”
Response:
>add/ITXS_”cr”
CLK_xxx”cr”
Selected Transmit Clock Activity (OK/FLT)
DRP_xxx”cr”
Drop (OK/FLT)
TXD_xxx”cr”
Transmit Data (OK/FLT)
SFLT_xx”cr””lf”]
Number of Stored Faults Logged (0 to 10)
5.7 Interface Receive Side Status
Command:
<add/IRXS_”cr”
Response:
add/IRXS_”cr”
MUX_xxx”cr”
MUX Lock (OK/FLT)
CLK_xxx”cr”
Selected Insert Clock Activity (OK/FLT)
INS_xxx”cr”
Insert (OK/FLT)
BWA_xxx”cr”
Receive Backward Alarm (OK/FLT)
BER_xxx”cr”
Frame BER (OK/FLT)
RXD_xxx”cr”
Receive Data Loss/AIS (OK/FLT)
OVFL_xxx”cr”
Buffer Overflow (OK/FLT)
UNFL_xxx”cr”
Buffer Underflow (OK/FLT)
IRES_xxxx_n.nE-e”cr”
Read Error Status
IBFS_nn%”cr”
Interface Buffer Fill Status
SFLT_xx”cr””lf”]
Number of Stored Faults Logged (0 to 10)