Comtech EF Data MD2401 User Manual
Page 39

MD2401 L-Band Multi Demod Installation and Operation Manual
User Interfaces
MN-MD2401
4–7
Revision 7
ReedSolomon:
{ENABLED, DISABLED}
Allows the user to Enable/Disable the Reed-Solomon Encoder.
RS N Value:
{Refer to Table 3-1 for valid n/k values}
Displays the currently used N value, Reed-Solomon Codes. In
Closed Net Mode, the user may select custom R-S Codes if
optional Reed Solomon Card is installed.
RS K Value:
{Refer to Table 3-1 for valid n/k values}
Displays the currently used K value, Reed-Solomon Codes. In
Closed Net Mode, the user may select custom R-S Codes if
optional Reed Solomon Card is installed.
RS Interleaver Depth:
{4, 8}
Allows the user to select the Reed-Solomon interleaver depth.
In Closed Net Mode, a depth of 4 or 8 may be selected.
Figure 4-3. Event Buffer Menu