OPERATING HEATER

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater
Turn control knob clockwise

Clockwise

to the OFF

position.

Shutting Off Burners Only (pilot stays lit)
Turn control knob clockwise

Clockwise

to the PI-

LOT position.

THERMOSTAT CONTROL

OPERATION

The thermostat control knob can be set to any
comfort level between HI and LO. The ther-
mostat will gradually modulate the heat out-
put and flame height from higher to lower set-
tings, or pilot, in order to maintain the comfort
level you select. The ideal comfort setting will
vary by household depending upon the amount
of space to be heated, the output of the central
heating system, etc.
Note:

Selecting the HI setting with the control

knob will cause the burner to remain fully on,
without modulating down in most cases.

MANUAL LIGHTING

PROCEDURE

1. Follow steps 1 through 5 under Lighting

Instructions on page 21.

2. Depress control knob and light pilot

with match.

3. Keep control knob pressed in for 30 sec-

onds after lighting pilot. After 30 seconds,
release control knob. Now follow step 8
under Lighting Instructions
, page 21.

BURNER PRIMARY AIR HOLES

Air is drawn into the burner through the holes in
the fitting at the entrance to the burner. These holes
may become blocked with dust or lint. Periodi-
cally inspect these holes for any blockage and clean
as necessary. Blocked air holes will create soot.

MAIN BURNER

Periodically inspect all burner flame holes with the
heater running. All slotted burner flame holes should
be open with yellow flame present. All round burner
flame holes should be open with a small blue flame
present. Some burner flame holes may become
blocked by debris or rust, with no flame present. If
so, turn off heater and let cool. Remove blockage,
blocked burner flame holes will create soot.

INSPECTING BURNERS

Check pilot flame pattern and burner flame pat-
terns often.

PILOT FLAME PATTERN

Figure 30 shows a correct pilot flame pattern. Fig-
ure 31 shows an incorrect pilot flame pattern. The
incorrect pilot flame is not touching the thermocouple.
This will cause the thermocouple to cool. When the
thermocouple cools, the heater will shut down.

Figure 30 - Correct Pilot Flame Pattern

Figure 31 - Incorrect Pilot Flame Pattern

Pilot Burner

Thermocouple

Pilot Burner

Propane/LP

Natural Gas

Pilot Burner

Pilot Burner

Thermocouple

Propane/LP

Natural Gas

If pilot flame pattern is incorrect, as shown in
Figure 31
• turn heater off (see To Turn Off Gas to Appli-

ance, page 20 [manually-controlled models] or
page 22 [thermostatically-controlled model])

• see Troubleshooting, page 25
Note:

The pilot flame on natural gas units will

have a slight curve, but flame should be blue and
have no yellow or orange color.