OBSERVED PROBLEM

Heater shuts off in use (ODS op-
erates)

Gas odor even when control knob
is in OFF position

Gas odor during combustion

Log set cycles to pilot, but room
temperature drops to a lower than
ideal level before log set comes
back on

POSSIBLE CAUSE

1. Not enough fresh air is avail-

able

2. Low line pressure

3. ODS/pilot is partially

clogged

1. Gas leak. See Warning

statement on page 27

2. Control valve defective

1. Foreign matter between con-

trol valve and burner

2. Gas leak. See Warning

statement on page 27

1. Thermostat sensing bulb

needs to be repositioned

REMEDY

1. Open window and/or door for

ventilation

2. Contact local natural or pro-

pane/LP gas company

3. Clean ODS/pilot (see Cleaning

and Maintenance, page 23)

1. Locate and correct all leaks (see

Checking Gas Connections,
page 15)

2. Replace control valve

1. Take apart gas tubing and re-

move foreign matter

2. Locate and correct all leaks (see

Checking Gas Connections,
page 15)

1. Reposition thermostat sensing

bulb (see Optional Positioning
of Thermostat Sensing Bulb
,
page 28

TROUBLESHOOTING

Continued

OPTIONAL POSITIONING

OF THERMOSTAT

SENSING BULB

FOR MASONRY AND FACTORY-
BUILT METAL FIREPLACE

If your log set cycles to pilot, but the room tem-
perature drops to a lower than ideal comfort level
before the log set comes back on, you may want
to reposition the thermostat sensing bulb.
The thermostat sensing bulb is located near the
gas valve assembly on the mounting bracket. This
location allows the thermostat to keep the room
temperature at an ideal comfort level for most fire-
place applications. For positioning the thermostat
sensing bulb elsewhere, an adhesive-backed
mounting clip is available.
Tools needed: 1/4" hex driver or socket
1. Remove logs. Locate the gas valve assembly

and thermostat sensing bulb (see Figure 34).

2. With 1/4" hex driver or socket, loosen the ther-

mostat screw. Carefully slide the thermostat
sensing bulb out of the retaining clamp (see
Figure 36, page 29).

Note:

Do not remove the screw. Make sure

you tighten the screw after removing the ther-
mostat sensing bulb.
IMPORTANT:

Do not force or bend the ther-

mostat sensing bulb or capillary.

Thermostat
Sensing Bulb

Figure 34 - Location of Gas Valve

Assembly and Thermostat Sensing Bulb

Gas Valve
Assembly

Mounting
Bracket

Figure 35 - Adhesive-backed Mounting

Clip