Note:

Home owners generally prefer to operate their heater

with the chimney damper closed. This will put all the heat into
the room. However, there may be times you will desire the full
flames of the HI heat setting but will find the heat output
excessive. You can open the chimney damper (if you have one)
fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has

been running.

1.

STOP! Read the safety information on page 17, column 2.

2.

Make sure equipment shutoff valve is fully open.

3.

Turn control knob clockwise

Clockwise

to the OFF position.

4.

Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Fol-
low “B” in the safety information, page 17, column 2. If
you don’t smell gas, go to the next step.

5.

Turn control knob counterclockwise

to the PILOT

position. Press in control knob for five (5) seconds (see
Figure 29).

Note:

You may be running this heater for the first time

after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds or more. This will al-
low air to bleed from the gas system.

6.

With thermostat control knob pressed in, press and release
ignitor button. This will light pilot. The pilot is attached to
the front burner. If needed, keep pressing ignitor button
until pilot lights.

Note:

If pilot does not stay lit, contact a qualified service

person or gas supplier for repairs. Until repairs are made,
light pilot with match. To light pilot with match, see Manual
Lighting Procedure
on page 19.

7.

Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.
• If control knob does not pop out when released, contact

a qualified service person or gas supplier for repairs.

Note:

If pilot goes out, repeat steps 3 through 7. This heater

has a safety interlock system. Wait one (1) minute for sys-
tem to reset before lighting pilot again.

8.

Turn control knob counterclockwise

to desired

heating level. The front burner should light. Set control
knob to any heat level between HI and LO.

9.

To light the rear yellow flame burner, push in and turn
rear burner control knob counterclockwise

to the

ON position.

OPERATING HEATER

Continued

Figure 29 - Control Knob(s) and Ignitor Button Locations

Models: CSG3924NT, CSG3924PT, VRL24NT, VRL24PT, VRL30NT
and VRL30PT

Ignitor Button

Control Knob

Rear Burner
Control Knob

Figure 30 - Pilot (Propane/LP)

TO TURN OFF GAS TO APPLIANCE

CAUTION: Do not try to adjust heating levels by

using the equipment shutoff valve.

Shutting Off Heater

1.

Turn control knob clockwise

to the OFF position.

2.

Turn rear burner control knob clockwise

to the

OFF position.

Shutting Off Burners Only (pilot stays lit)

1.

Turn control knob clockwise

to the PILOT position.

2.

Turn rear burner control knob clockwise

to the

OFF position.

OPERATING HEATER (THERMOSTAT-CONTROLLED MODELS)

Lighting Instructions (Cont.)
To Turn Off Gas To Appliance

Ignitor Electrode

Pilot Burner

Thermocouple

Figure 31 - Pilot (Natural)

Ignitor
Electrode

Pilot Burner

Thermocouple