Maintenance and Troubleshooting

4-10

Entire display fails to work.

•

Check for proper line voltage into the power

termination panel.

•

Check for correct power to controller and

modules.

•

Check/replace the ribbon cable from the

controller to the modules.

•

Check the voltage settings on the power

supplies.

•

Check/replace the signal cable to the

controller.

•

Replace the controller.

•

Verify proper use of the software in the V1500

Controller manual (ED13530).

Temperature always reads –196F/-127C
degrees F/0 degrees C

•

Check temperature sensor connections.

•

Replace the temperature sensor.

•

Replace the controller.

Display is stuck on bright or dim.

•

Check Manual/Auto dimming in Venus 1500

software.

•

Check light detector cable.

•

Check the address on the Light Sensor.

•

Check light detector for obstructions.

•

Replace the light detector.

•

Replace the controller.

4.10 Initialization Operation Information

Every time the display is operated, the display will run through an initialization in
which it will display the following:


1. Product Name (Galaxy®)
2.
Display Size (Row x Column)
3.
Shading (64 Mono)
4.
Bootloader Version (OS X.XX)
5.
Firmware Number (ED-13305)
6.
Firmware Revision (Rev X.XX)
7.
Hardware Address (HW:XX)
8.
Software Address (SW:XX)
9.
IP Address: ((default) IP: 172.16.192.25)
10.
Subnet Msk: ((default) Msk: 255.255.0.0)
11.
COM1 Configuration (C1:V15) ((Modem C1:V15) If a Modem is present)
12.
COM 2 Configuration (C2: RTD)
13.
Socket 3001: (IP 3001: V15)
14.
Socket 3002: (IP 3002: RTD)
15.
Line Frequency (CLK: AUTO (60))
16.
Display Name Description (Galaxy Row x Column)