Pace Clock Mode Operation, Menus & Settings

MENU-SETUP
6-NETWORK

MENU-SETUP
1-NETWORK ENABLE

MENU-NETWORK
2-I P ADDRESS

I P ADDR- OMNI 1
192*168. 0. 55

MENU-NETWORK
3-SUBNET MASK

11.14 Setup Network Menu

This menu is used to configure various network settings for
outputting Real-Time Data (RTD) to displays.

Network Enable

This menu sets the ETHERNET jack output on or off. If the
jack is not needed, it can be turned OFF (default).





Use [←][→] to toggle between ON/OFF and then press [ENTER] to save.

Note: If this setting is set to OFF, all of the menus below will be disabled.

IP Address

This menu allows the operator to set or verify the IP address
of the console. The default setting is shown below.





In most cases, the standard IP address should be selected.
Press [1] followed by [ENTER] and the display will verify
the console’s IP address. The standard IP address varies by
console name as shown in the table at right.

If a custom IP address is required, such as for connecting to
a non-Daktronics network, press [2] followed by [ENTER].
Press the [0]-[9] keys to enter a new value for each group of
numbers and press [ENTER] after every group. To select a
standard address instead, press [CLEAR] twice to exit the menu.

Note: Once the console has been successfully connected to a network, it must be
disconnected from the network in order to change the IP address settings.

Subnet Mask

The subnet mask may only be edited if the IP address is set
to custom. The default setting is shown below.





Press the [0]-[9] keys to enter a new value for each group of numbers and press [ENTER]
after every group. If no change is needed, press [CLEAR] twice to exit the menu.

Name

IP Address

OMNI1 192.168. 0. 55
OMNI2 192.168. 0. 56
OMNI3 192.168. 0. 57