Dt6upgrade, Usage for tcp/ip endpoints – Datatek DT-7000 Utilities User Manual

Page 16

Advertising
background image

U t i l i t i e s - D T 6 b a c k u p , D T 6 r e l o a d , D T 6 u p g r a d e – R e l e a s e 3 . 0

D T 7 b a c k u p , D T 7 r e l o a d

02/04/10

Datatek Applications Inc.

16

4.5 DT6

UPGRADE

This utility requires the minimum level or higher of the platform software (see Table 1: Minimum Platform
Software, page 5).

4.5.1 U

SAGE FOR

TCP/IP

E

NDPOINTS

Syntax: dt6upgrade -i [-v] [-d] [-V] [–p<pass>] [-P] -sa

<IP-ADDR> [–t<TCP#>] <filename>

Where:

-v Print

Version

of

the Utility, then exit

-d

Connection Debug (verbose) print enable

-V

Abbreviated Debug (verbose) showing runtime progress of the utility

-p<pass>

Password for logging into the DT product (Default is “initial”)

-P

As an alternative to supplying the –p<pass> option, -P causes dt6reload to prompt for
the unit password when it is needed. The password is not echoed.

-i

Specifies that a TCP/IP connection is to be used

-t<TCP#>

Override the standard TCP/IP Port number (Default is 1023)

-sa

(Required) Use direct file transfer from the host to the unit. This requires the minimum
level or higher of the platform software.

<IP-ADDR>

The IP address of the DT product console

<filename>

The filename including its directory string, if necessary, on this host containing the
new software package.

The

–sa

option must be given in the command line.

Advertising