>5s

1

0

EXIT

1

2

3

4

5

1

0

MENU 2

Measured temperature correction
(-5°C à +5°C par pas de 0,1°C).

Example: If the temperature displayed
on the device is 19°C and the
observed temperature is 20°C,
adjust the temperature by +1°C, then
confirm by pressing OK.

- 5°C <

< +5°C

Before changing this setting,

the device must have been in
operation for at least 2 hours.

Temperature displayed in AUTO mode

0 : Continuous display of the
temperature setting.
In this case, press the i
button to display the room temperature
1 : Continuous display of the
room temperature.
In this case, press the

i button

to display the temperature setting.

Time display mode

12h-24h

24h

12h

Automatic time change
(summer/winter time)

Time before boiler maintenance
(0 to 365 days)

Reprogramme after
each maintenance operation

--- (0) to 365 days

0,2°C <

< 2°C

Hysteresis

0,4°C

Control time base

If you choose an "on/off" type setting,

you can adjust the hysteresis

(or differential) via menu 2-11

Minutes

Minutes

Minutes

Minutes

On/Off

Resetting the boiler operating time

meter

No

Yes

Permission to change
Programme and settings

0 : Modifications permitted to
programme and settings

1 : Modifications to programme
not permitted and adjustment of
settings limited.
Tybox 137: Comfort setting
limited between 16 and 22°C.
Tybox 237-337: +/- 3°C either
side of the last setting.

: 5°C <

< 30°C

: 5°C <

< 16°C

+/- 3°C

PROG

Press button 2.
To change the different settings, press the + or - but-
tons, then press the OK button to confirm and move
on to the next setting.

Turn the selector dial to

,

then press the

i button for 5

seconds.

To exit the mode,
turn the selector dial
to another mode.