Switch configurations, Sw1: macro slave node configure, Sw2: macro master number select – Delta Tau MACRO CPU BOARD 4Ax-602804-xHxx User Manual

Page 19

Advertising
background image

MACRO-CPU Hardware Reference

Switch Configurations

SW1: MACRO Slave Node Configure

SW1

Setting

# of Servo

Channels

& Nodes

Used

MACRO

Servo

Nodes

Specified

Station

Channel

Nos.

Station

Channel

Starting

Addresses

1

st

Axis

Board

Servo

IC

2

nd

Axis

Board

Servo

IC

PMAC2's I996

Value **

(Turbo

PMAC2’S
I6840, etc.

PMAC2's I1000,

I1002 Value

(Turbo

PMAC2’s I70,

I71, etc.)

0

(default)

4

0, 1, 4, 5

1, 2, 3, 4

$C000, $C008,
$C010, $C018*

4-axis None

$F8033 $0033

1

4 8,

9,

12,

13

1, 2, 3, 4

$C000, $C008,
$C010, $C018*

4-axis None

$FB300 $3300

2

2

0, 1

1, 2

$C000, $C008*

4-axis

None

$F8003

$0003

3

2

4, 5

3, 4

$C010, $C018*

4-axis

None

$F8030

$0030

4

2

8, 9

1, 2

$C000, $C008*

4-axis

None

$F8300

$0300

5

2

12, 13

3, 4

$C010, $C018*

4-axis

None

$FB000

$3000

6

6

0, 1, 4, 5,
8, 9

1, 2, 3, 4,
5, 6

$C000, $C008,
$C010, $C018,
$C020, $C028*

4-axis 4-axis

$F8333 $0333

7

8

0, 1, 4, 5,
8, 9, 12,
13

1, 2, 3, 4,
5, 6, 7, 8

$C000, $C008,
$C010, $C018,
$C020, $C028,
$C030, $C038*

4-axis 4-axis

$FB333 $3333

8

2

0, 1

9, 10

$C090, $C098

2-axis

None

$F8003

$0003

9

2

4, 5

9, 10

$C090, $C098

2-axis

None

$F8030

$0030

10

2

8, 9

9, 10

$C090, $C098

2-axis

None

$F8300

$0300

11

2

12. 13

9, 10

$C090, $C098

2-axis

None

$FB000

$3000

12

6

0, 1, 4, 5,
8, 9

1, 2, 3, 4,
9, 10

$C000, $C008.
$C010, $C018,*
$C090, $C098

4-axis 2-axis

$FB333 $0333

13

0

(I/O only)

None None None

None

None $F8000 $0000

14

(Reserved For

Future Use)

15

***

0 11 -

- -

- $F8800

-

* These addresses are for stack axis boards. Add $40 to these addresses for backplane axis boards.

** Other bits of this I-variable may also be set to enable I/O nodes or other slave stations it is commanding

*** A setting of 15 forces the station to use its factory default I-variables on power-up/reset.


SW2: MACRO Master Number Select

0: Commanded from Master IC # 0

1: Commanded from Master IC # 1


F: Commanded from Master IC # F (15)

3U MACRO-CPU Jumper and Switch Configurations

15

Advertising