The Stage Box – VIS‐4832

 Analog Returns (outputs) – The (8) returns are connected via 

a single DB25 connector. Returns are line level. 

 Digital Returns (outputs) – The (8) digital returns are 

connected via a single DB25 connector. Returns are all AES 
digital. 

 Sends (inputs) – The (32) AES digital inputs on the VIS‐4832 

are connected via (2) DB25 connectors, (16) channels per DB25 
connector. 

 Fiber Connections – The VIS‐4832 has a primary fiber 

connector standard. The fiber connector marked “primary” needs 
to be connected to a VIM‐1832 at all times as the VIM‐1832 
provides the system clock. There are also (2) additional (optional) 
fiber outputs from the VIS‐4832 that would connect via fiber to 
VIM‐1032 mixer boxes. Always be certain to use appropriate fiber 
and connectors. LightViper systems use multimode fiber. Single 
mode optics are available on a custom basis for situations where 
single mode fiber may already exist. 

 Control Circuits Connector – This RJ45 connector provides 

(3) bi‐directional CMOS or TTL data lines (up to 38.4KHz from 
Stage to FOH and 2MHz from FOH to stage) plus voltage and 
GND. This connector is used in conjunction with DGL‐422 cables 
for transporting Yamaha control, or with MD3 units to transport 
RS‐422, RS‐232 or MIDI. THIS IS NOT AN ETHERNET CONNECTOR 
– CONNECTING AN ETHERNET DEVICE TO THIS CONNECTOR 
COULD DAMAGE THE DEVICE. The pin outs for this connector are 
detailed in the appendix. Most CMOS or TTL functions / 
equipment can be adapted to make use of this connector.

 Sync LED – This LED indicates the status of the fiber‐optic 

link between the stagebox (VIS‐4832) and mixer box (VIM‐1832). 
It has three states; SOLID RED indicates there is no sync present; 
ALTERNATING RED & GREEN indicates the unit is searching for 
sync; SOLID GREEN indicates sync is present (optical link) and OFF 
indicates no power. 

 Power Connector / Fuse – The AC power connection to the 

VIS‐4832 is made via a supplied IEC power cord. The internal 
power supply can accept 90‐260V at either 50 or 60 Hz> The 
power fuse is a 5x20mm, 1A Slo‐Blo. Only replace the fuse with 
an exact match. If after replacement the fuse blows again, 
contact Fiberplex for service. 