Introduction 

Complementing the flexibility of the FiberPlex ‘TD Series’ of fiber optic modules, the TDP provides front of rack 
connection, mounting, power, and cable management for up to 6 front facing TD modules in a compact and 
rugged aluminum 1U rack. Each of the 16 channels of the modular TDP front panel can accommodate any 
Neutrik™ D Series connector, LC and ST barrel connectors, DB9 connectors, etc. The unused positions are 
simply fitted with a blank panel. The integrated key‐hole mounting holes on the bottom of the TD units lock 
securely on mating studs while a rear retention bar holds them securely in place. A 6 position power wiring 
harness and included power adapter provide, not just 9 VDC power, but a positive earth ground to the 
modules via 3 position Phoenix™ locking power connectors.  Managing all that cabling and fiber can 
sometimes be quite a chore, the TDP allows a simple solution to put maximum capacity and flexibility into a 
single 1U space. 

Key Features 

Provides mounting and power for up to 6 single wide or 3 double wide TD Series 
modules 

Perfect for front of rack connections 

Accommodates up to 16 connector positions 

Plates available for standard Neutrik™ D Series connectors, LC and ST barrels, DE‐9, etc 

Selected connectors included 

Reconfigure in minutes 

Securely seats modules with positive retention bar 

Power adapter and wiring harness included 

Convenient cable tray for clean installation 

Grounding stud for positive earth ground 

Reinforced rack ears 

Getting Started 

Initial Inspection 

Immediately upon receipt, inspect the shipping container for damage. The container should be retained until 
the shipment has been checked for completeness and the equipment has been checked mechanically and 
electrically. If the shipment is incomplete, if there is mechanical damage, or if the unit fails to operate notify 
FiberPlex and make the shipping materials available for the carrier's inspection. 

Chassis Mounting 

Mount the empty chassis using fasteners appropriate to your standard 19” rack enclosure. All four (4) 
mounting points MUST be utilized. Ensure that there exists adequate clearance for ventilation. The chassis 
should be located in an environment where an ambient temperature between 0° and 50° C can be maintained. 

Power Requirements  

Any combination of 6 FiberPlex TD Series Modules can be mounted in a TDP. Each TD module can draw as 
much as 500 mA at 9VDC, so with the maximum 6 modules installed the maximum power requirement for a 
power adapter is 3A at 9V or 18 Watts. Power is supplied to the individual modules through a pre‐wired Power 
Harness that connects to the modules using a 3 pin Phoenix™ connector. Two pins supply the 9 VDC and the 
third pin connects a positive earth ground to a ground lug on the rear of the TDP. For best performance it is 
recommended to connect the ground lug to a known good earth ground. DC power is supplied to the Power 
Harness through the included power adapter connected to the rear circular connector.