2.4 Storage

Store the pump in a clean, dry

location away from vibration. Leave piping
connection covers in place to keep dirt and other
foreign material out of pump casing. Turn pump at
intervals to prevent brinelling of the bearings and the
seal faces, if fitted, from sticking.

Do not store pumps starting on the fan guard.

The pump may be stored as above for up to 6
months. Consult Flowserve for preservative actions
when a longer storage period is needed.

2.5 Recycling and end of product life

At the end of the service life of the product or its
parts, the relevant materials and parts should be
recycled or disposed of using an environmentally
acceptable method and local regulations. If the
product contains substances which are harmful to
the environment, these should be removed and
disposed of in accordance with current regulations.
This also includes the liquids and or gases in the
"seal system" or other utilities.

Make sure that hazardous substances or toxic

fluid are disposed of safely and that the correct
personal protective equipment is used. The safety
specifications must be in accordance with the
current regulations at all times.

3 PUMP DESCRIPTION

3.1 Configurations

The MEN pump is a single-stage centrifugal pump
with an axial inlet and a vertical outlet. The
dimensions of the volute pump casing, of the suction
and discharge diameters, of the settlement feet as
well as of the shaft end diameter and position
correspond to standards DIN 24255 and NF EN 733
for pumps supplied with EN flanges. Flanges may
also be supplied to ANSI standards and in this case
please refer to the drawing for the position of the
flanges.

The pump must be stored in a non-explosive,

ventilated location, sheltered from bad weather, dust
and vibrations.

The reliability of the delivered machine can only be
ensured if it is used according to the conditions
given in this manual. The maximum values specified
in this manual must never be exceeded.

Maximum working pressure at discharge

................................................ 16 bars (232 psi)

Maximum working pressure at suction

................................................ 10 bars (145 psi)

Maximum pumped fluid temperature

- Gland packing ......................

105 °C (221 °F)

- Mechanical seal ...................

120 °C (248 °F)

Minimum pumped fluid temperature

.................................................... -10 °C (14 °F)

Maximum ambient temperature

.................................................... 40 °C (104 °F)

Maximum solid suspension
....................................... 50 g/m

3

(0.003 lbm/ft

3

)

Density................................. 1

Viscosity .............................. 1 mm

2

/s (31 SSU)

Rotation speed (frequency 50 Hz)

- MEN ............................................... 1450 min

-1

- MEN ............................................... 2900 min

-1

Rotation speed (frequency 60 Hz)
- MEN ............................... 1750 (or) 3500 min

-1

The maximum speed may be shown

on the pump nameplate.