5 piping – Flowserve MEN User Manual

Page 19

Advertising
background image

MEN USER INSTRUCTIONS ENGLISH 71576288 - 02/13

Page 19 of 36

flowserve.com

Pump and motor mounted on individual base

plates:
Machines are (or must be) first mounted on their
own base plate in the workshop. Once the pump is
set, it will be regarded as the fixed piece. Any
alignment necessary shall be carried out on the
motor.

Never connect the electric motor

before the setting has been completely finished.

4.5 Piping

The user must verify that the equipment is

isolated from any external sources of vibration.

Protective covers are fitted to the

pipe connections to prevent foreign bodies entering
during transportation and installation. Ensure that
these covers are removed from the pump before
connecting any pipes.

4.5.1 Suction and discharge piping
The dimensions of the pipes do not directly depend
on suction and discharge diameters of the pump:

a) First, choose a flow speed < 2 m/s (7 ft/s) at

suction, and about 3 m/s (10 ft/s) at discharge.

b) Take into account the available NPSH, which

must be superior to the required NPSH of the
pump.

Never use pump as a support for

piping.

Do not mount expansion joints in

such a way that their force, due to internal pressure,
may act on the pump flange.

Maximum forces and moments allowed on the pump
flanges vary with the pump size and type. These
external strains may cause misalignment, hot
bearings, worn couplings, vibrations and the
possible failure of the pump casing. When designing
the pipes (§ 4.5.2.1, § 4.5.2.2, § 4.5.3.1) take
necessary precautions in order not to exceed
maximum allowed strains.

Forces and moments applied to the pump flanges
must never exceed the values shown in the table
below:

MEN

Pump

Suction DNA

Discharge DNR

Forces

Moments

mm

in

mm

in

Fv max

Fh max

ΣΣΣΣ

Mt max

daN

lbf

daN

lbf

m.daN

lbf.ft

50-32-125

50

2.0

32

1.25

125

281

95

214

20

148

50-32-160

50

2.0

32

1.25

125

281

95

214

17

125

50-32-200

50

2.0

32

1.25

125

281

95

214

17

125

50-32-200L

50

2.0

32

1.25

125

281

95

214

17

125

65-40-125

65

2.5

40

1.5

135

304

100

225

22

162

65-40-160

65

2.5

40

1.5

135

304

100

225

22

162

65-40-200L

65

2.5

40

1.5

135

304

100

225

20

148

65-40-250

65

2.5

40

1.5

135

304

100

225

25

185

65-40-250L

65

2.5

40

1.5

135

304

100

225

25

185

65-50-125

65

2.5

50

2.0

135

304

100

225

22

162

65-50-160

65

2.5

50

2.0

135

304

100

225

22

162

65-50-200L

65

2.5

50

2.0

135

304

100

225

20

148

65-50-250L

65

2.5

50

2.0

135

304

100

225

25

185

80-65-125

80

3.0

65

2.5

145

326

105

236

27

199

80-65-160

80

3.0

65

2.5

145

326

105

236

27

199

80-65-200L

80

3.0

65

2.5

145

326

105

236

27

199

80-65-250L

80

3.0

65

2.5

145

326

105

236

27

199

80-65-315

80

3.0

65

2.5

145

326

105

236

27

199

100-80-160

100

4.0

80

3.0

180

405

125

281

47

347

100-80-200L

100

4.0

80

3.0

180

405

125

281

47

347

100-80-250L

100

4.0

80

3.0

180

405

125

281

47

347

100-80-315

100

4.0

80

3.0

180

405

125

281

47

347

125-100-200L

125

5.0

100

4.0

320

720

190

427

95

701

125-100-250L

125

5.0

100

4.0

330

742

200

450

102

753

125-100-315

125

5.0

100

4.0

310

697

185

416

92

679

125-100-315L

125

5.0

100

4.0

310

697

185

416

92

679

125-100-400

125

5.0

100

4.0

285

641

170

382

82

605

125-100-400L

125

5.0

100

4.0

285

641

170

382

82

605

150-125-250L

150

6.0

125

5.0

450

1012

290

652

155

1144

150-125-315L

150

6.0

125

5.0

415

934

260

585

140

1033

150-125-400L

150

6.0

125

5.0

410

922

255

574

137

1011

200-150-315L

200

8.0

150

6.0

500

1125

325

731

175

1292

200-150-400L

200

8.0

150

6.0

500

1125

325

731

175

1292

Advertising