DS USER INSTRUCTIONS ENGLISH 71576283 - 02/13

02

Page 29 of 36

flowserve.com

Viscosity grade ISO 46
Ambient temperature
Bearings temperature 80 °C (176 °F) maximum

TABLE OF EQUIVALENCE AND CHARACTERISTICS

OF RECOMMENDED OILS

MANUFACTURER TYPE

CHARACTERISTICS

BP

ENERGOL

HLP

46

ELF

TURBELF

SA

46

ESSO

TERESSO

46

MOBIL

DTE

MEDIUM

SHELL

TELLUS

T

37

TOTAL

PRESLIA

46

TOTAL

AZOLLA

ZS

46

Density at 15 °C (59 °F)

0.885

0.881

0.868

0.878

0.87

0.872

0.877

Viscosity at 40 °C (104 °F).cSt

45

48.6

43

43

46

46

46

Viscosity at 50 °C (122 °F).cSt

30

31.5

29.4

28

30

29.5

30

Viscosity at 100 °C (212 °F).cSt

6.9

7.1

6.7

7

6.9

6.9

6.8

Pour-point °C / °F

- 30

- 22

- 27

- 17

- 12

10.4

- 15

5

- 30

- 22

- 12

10

- 21

- 6

Flash-point °C / °F

210

410

220

428

220

428

220

428

214

417

230

446

230

446

Fire-point °C / °F

240

464

252

486

280

536

240

464

245

473

Aniline point °C / °F

99

210

102

216

110

230

102

216

109

228

101

214

101

214

Viscosity index

105

106

109

105

113

100

100

Acid value

0.2

0.6

0.2

0.13

0.7

0.1

0.7 to 1.2

Color

1 ½

2

1

2

2

1 ½

1

Antierosion additives

yes

yes

yes

yes

yes

Foam inhibitors

yes

yes

yes

yes

yes

yes

yes

Anticorrosion additives

yes

yes

yes

yes

yes

yes

yes

Antioxidant

yes

yes

yes

yes

yes

yes

yes

Conradson carbon residue

0.01

0.2

Limits on temperature °C / °F

- 12 to

120 °C (10

to 248 °F)

- 21 to

110 °C (- 6

to 230 °F)

Saponification

< 0.5

1.2

6.2.5 Gland packing

6.2.5.1 Pump fitted with a packed gland
A well run in and correctly adjusted packing gland
requires little maintenance. If, after some time, the
leakage becomes too great, the gland should be
tightened again in order to return these to a normal
level.

If re-tightening is not possible, new packing must be
installed

6.2.5.2 Gland packing inspection and removal
a) Remove the shield guards.
b) Slide back the gland.
c) Remove the packing rings with an extractor

designed for this purpose (including the lantern
ring if it exists; note its position and its direction
of rotation).

d) Inspect the state of the sleeve surface; the

presence of many marked grooves will indicate
that it must be replaced.

e) Carefully clean the different pieces of the

packing gland.

6.2.5.3 Gland packing fitting
If the packing is supplied as cord the packing must
be cut so that the external diameter is lightly
tightened and there is an initial gap between the
sleeve and the packing ring.

For that purpose, wind the packing helically around
the shaft sleeve or a chuck of the same diameter.
(Take precautions to avoid damaging sleeve).

Example of straight cut

Example of bevel cut

Ensure a tightening on the stuffing

box housing and not on the sleeve.

SETTING OF PACKING