CPXS, CPXNS and CPXPS USER INSTRUCTIONS ENGLISH 71569250 07-11

Page 8 of 48

flowserve.com

Additional requirements for CPXPS pumps only
Where the system operation does not ensure control of
priming, as defined in the User Instructions, and the
maximum permitted surface temperature of the T Class
could be exceeded, the user shall fit an external surface
temperature protection device.

1.6.4.4

Preventing the build up of explosive
mixtures

ENSURE THE PUMP IS PROPERLY FILLED

AND VENTED AND DOES NOT RUN DRY

Ensure the pump and relevant suction and discharge
pipeline system is totally filled with liquid at all times
during the pump operation, so that an explosive
atmosphere is prevented. In addition it is essential to
make sure that any heating and cooling systems are
properly filled.

If the operation of the system cannot avoid this
condition, fit an appropriate dry run protection device
(for example liquid detection or a power monitor).

To avoid potential hazards from fugitive emissions of
vapour or gas to atmosphere the surrounding area
must be well ventilated.

1.6.4.5

Preventing sparks

To prevent a potential hazard from mechanical

contact, the coupling guard must be non-sparking fro
category 2 equipment.

To avoid the potential hazard from random induced
current generating a spark, the baseplate must be
properly grounded.

Avoid electrostatic charge: do not rub non-metallic

surfaces with a dry cloth

;

ensure cloth is damp.


For ATEX the coupling must be selected to comply
with 94/9/EC. Correct coupling alignment must be
maintained.

Additional requirement for metallic pumps on
non-metallic baseplates

When metallic components are fitted on a non-
metallic baseplate they must be individually earthed.

1.6.4.6

Preventing leakage

The pump must only be used to handle liquids

for which it has been approved to have the correct
corrosion resistance.

Avoid entrapment of liquid in the pump and associated
piping due to closing of suction and discharge valves,
which could cause dangerous excessive pressures to
occur if there is heat input to the liquid. This can occur
if the pump is stationary or running.

Bursting of liquid containing parts due to freezing
must be avoided by draining or protecting the pump
and ancillary systems.

Where there is the potential hazard of a loss of an
external flush, the fluid must be monitored.

If leakage of liquid to atmosphere can result in a
hazard, install a liquid detection device.

1.6.4.7

Maintenance to avoid the hazard

CORRECT MAINTENANCE IS REQUIRED

TO AVOID POTENTIAL HAZARDS WHICH GIVE A
RISK OF EXPLOSION

The responsibility for compliance with
maintenance instructions is with the plant
operator.

To avoid potential explosion hazards during
maintenance, the tools, cleaning and painting
materials used must not give rise to sparking or
adversely affect the ambient conditions. Where
there is a risk from such tools or materials,
maintenance must be conducted in a safe area.

It is recommended that a maintenance plan and
schedule is adopted. (See section 6, Maintenance.)