CASING BLIND COVER USER INSTRUCTIONS ENGLISH 75663450 04-10

2.3 Lifting

Pumps and motors often have integral

lifting lugs or eye bolts. These are intended for use in
only lifting the individual piece of equipment.

Do not use eye bolts or cast-in lifting

lugs to lift pump, motor and baseplate assemblies.

Care must be taken to lift components

or assemblies above the center of gravity to prevent
the unit from flipping. This is especially true with
In-Line pumps.

2.3.1 Lifting pump components

Casing Blind Cover [1220]
Insert an eye bolt in the tapped hole as provided.
Use either a sling or hook through the eye bolt.

2.4 Storage

Store the pump in a clean, dry location

away from vibration. Leave flange covers in place to
keep dirt and other foreign material out of pump
casing. The pump may be stored as above for up to
6 months. Consult Flowserve for preservative actions
when a longer storage period is needed.

2.4.1 Short term storage and packaging
Normal packaging is designed to protect the pump
and parts during shipment and for dry, indoor storage
for up to six months or less. The following is an
overview of our normal packaging:
All loose unmounted items are packaged in a

water proof plastic bag and placed under the
coupling guard

The internal surfaces of ferrous casings, covers,

flange faces, and the impeller surface are
sprayed with Cortec VCI-389, or equal

The pump must be stored in a covered, dry

location


2.4.2 Long term storage and packaging
Long term storage is defined as more than six
months, but less than 12 months. The procedure
Flowserve follows for long term storage of pumps is
given below. These procedures are in addition to the
short term procedure.
Each assembly is hermetically (heat) sealed from

the atmosphere by means of tack wrap sheeting
and rubber bushings (mounting holes)

Desiccant bags are placed inside the tack

wrapped packaging

This packaging will provide protection for up to

twelve months from humidity, salt laden air, dust
etc.

2.5 Recycling and end of product life

At the end of the service life of the product or its
parts, the relevant materials and parts should be
recycled or disposed of using an environmentally
acceptable method and in accordance with local
regulations. If the product contains substances that
are harmful to the environment, these should be
removed and disposed of in accordance with current
local regulations. This also includes the liquids
and/or gases that may be used in the "seal system"
or other utilities.

Make sure that hazardous substances are

disposed of safely and that the correct personal
protective equipment is used. The safety
specifications must be in accordance with the current
local regulations at all times.

3 DESCRIPTION
3.1 Configurations

The Casing Blind Covers are designed to replace the
back pull out unit and prevent product leakage during
maintenance.

3.2 Nameplate

The casing blind cover nameplate, at a minimum will
contain the following information:
Model – Description of pump model and size
MDP - Maximum design pressure at 38˚C(100˚F)
Material – Flowserve Material Code. See section 3.2

Figure 3-1: Nameplate mounted to blind cover

Serial No.

Equipment No.

Purchase Order

Model

Size

MDP

Material

Date DD/MMM/YY





Page 6 of 13