2 pressure-temperature ratings, 3 performance and operation limits – Flowserve Casing Blind Covers Metallic User Manual

Page 7

Advertising
background image

CASING BLIND COVER USER INSTRUCTIONS ENGLISH 75663450 04-10

Page 7 of 13

3.3 Performance and operation limits

3.3.1 Alloy cross reference chart
Figure 3-2 is the Alloy cross-reference chart for
Flowserve ASME (ANSI) pumps.

This product has been selected to meet the
specification of your purchase order. See section 1.5.

Figure 3-3 is the Alloy cross reference chart for
wrought casing blind covers.


The following data is included as additional information
to help with your installation. It is typical, and factors
such as liquid being pumped, temperature, material of
construction, and seal type may influence this data. If
required, a definitive statement for your application can
be obtained from Flowserve.


3.3.2 Pressure-temperature ratings
The pressure–temperature (P-T) ratings for blind
covers are shown in figure 3-4. Determine the
appropriate cover “Material Group No.” in Figure 3-2.
Interpolation may be used to find the pressure rating
for a specific temperature.

The following provides pressure-

temperature ratings for the blind covers only.
The lowest rating of all parts connected to the
casing must be used. Consult the user
instructions provided with the pump.


Example:
The pressure temperature rating for a Mark 3 GP2
blind cover, 316 construction, with an operating
temperature of 149˚C is found as follows:
a) From Figure 3-2, the correct material group is 2.2

Cover plate material compatibility is

the responsibility of the end user.

b) From Figure 3-4C, the pressure-temperature

rating is 21.5 bar.

Figure 3-2: Casing Blind Cover Alloy cross-reference chart

Flowserve

Material Code

Generic

Designation

Specifications

Material Group No.

D3041 316

Plate A240 Type 316 (UNS Designation S31600)

2.2

D3134

Steel Plate

A515 Gr. 70 (Gr. 485 - S.I. units)

1.1

Figure 3-3: Casing Cast Alloy cross-reference chart

Flowserve

Material Code

Generic

Designation

Durco Legacy

Codes

ASTM

Specifications

Material

Group No.

E3020

Ductile iron

DCI

A395, Gr. 60-40-18

1.0

E3033

High chrome iron

CR28

A532 class 3

Cr

E4027

High chrome iron

CR29

None

Cr

E4028

High chrome iron

CR35

None

Cr

C3009

Carbon steel

DS

A216 Gr. WCB

1.1

C3062

304

D2

A744, Gr. CF8

2.1

C3069

304L

D2L

A744, Gr. CF3

2.1

C3063

316

D4

A744, Gr. CF8M

2.2

C3067

316L

D4L

A744, Gr. CF3M

2.2

C3107

Duplex Stainless

CD4M

A995, Gr. CD4MCuN

2.8

C4028

Alloy 20

D20

A744, Gr. CN7M

3.17

C4029 Durcomet

5 DV

None

2.2

K3005

Inconel

600

DINC

A494, Gr. CY40

3.5

K3007

Monel

400

DMM

A494, Gr. M35-1

3.4

K3008

Nickel

DNI

A494, Gr. CZ100

3.2

K4007

Hastelloy

B

DC2

A494, Gr. N7M

3.7

K4008

Hastelloy

C

DC3

A494, Gr. CW6M

3.8

E3041

Duriron

D

A518, Gr. 1

No load

E3042

Durichlor 51

D51

A518, Gr. 2

No load

E4035

Superchlor

SD51

A518, Gr. 2

No load

D4036 Durco

DC8 DC8

None

-

H3004

Titanium

Ti

B367, Gr. C3

Ti

H3005

Titanium-Pd

TiP

B367, Gr. C8A

Ti

H3007

Zirconium

Zr

B752, Gr. 702C

Ti



Duriron, Durichlor 51 and Superchlor are registered trademarks of Flowserve Corporation.
Hastelloy is a registered trademark of Haynes International, Inc.
Inconel and Monel are registered trademarks of International Nickel Co. Inc.

Advertising