ERPN-M USER INSTRUCTIONS ENGLISH 02-08

Page 11 of 37

Power BHP

Power K w.

dB(A) Value

63

125

250

500

1K

2K

4K

8K

3

2.2

67

54

58

58

56

56

56

54

59

3.7

2.7

68

58

62

62

60

60

60

58

53

4.7

3.5

69

59

63

63

61

61

61

59

54

6

4.4

70

64

64

62

62

60

55

50

50

7.6

5.6

71

61

65

65

63

63

63

61

56

9.4

6.9

72

62

66

66

64

64

64

62

57

12

8.8

73

67

67

65

65

63

58

53

53

15

11.0

74

68

68

66

66

64

59

54

54

19

14.0

75

69

69

67

67

65

60

55

55

24

17.6

76

70

70

68

68

66

61

56

56

31

22.8

77

67

71

71

69

69

69

67

62

39

28.7

78

68

72

72

70

70

70

68

63

49

36.0

79

69

73

73

71

71

71

69

64

62

45.6

80

70

74

74

72

72

72

70

65

77

56.6

81

71

75

75

73

73

73

71

66

95

69.9

82

75

75

73

73

71

66

61

61

115

84.6

83

77

77

75

75

73

68

63

63

145

106.6

84

78

78

76

76

74

69

64

64

190

139.7

85

79

79

77

77

75

70

65

65

250

183.8

86

80

80

78

78

76

71

66

66

350

257.4

87

81

81

79

79

77

72

67

67

500

367.6

88

78

82

82

80

80

80

78

73

700

514.7

89

79

83

83

81

81

81

79

74

940

691.2

90

80

84

84

82

82

82

80

75

1100

808.8

91

81

85

85

83

83

83

81

76

Sound pressure readings are for information only and are not subject to guarantee by Flowserv e.

Decibel readings do not include driv er or sy stem nois e.
Pump tested at 100% of the bes t effic iency point at max.impeller diameter with water.

dB correction for combining noises (pump+mo tor)
Differen ce between two

levels to be comb ined, dB

Add to the hig her level to obtain

the combin ed noise leve l,dB

Note :

1) The values sh owed ar e mea sure d a t a distance of 1 mt. (horizontally) from major pump
surfa ces and 1.5 mt. abo ve the floor .

2) The values sh own are expressed in dB.

3) For Noise Test Pro ce dure refer to Works Standar d L -109-0
4) The values sh own have been de rive d from actua l no ise -test da ta and are ba se d on the fo llowin g con ditions:

-

Equ ipment is loca ted in a fre e field abo ve a reflectin g pl ane in which the reductionin noise level

in all directions is 6db in each o ctave ba nd fo r ea ch dou bling of distance.

-

Backgroun d n oise is 10dB minimum b elow al l no ise levels in e ach octave ba nd.

-

The val ues shown are at a dista nce of 1 meter (horizontally) fr om the ma jor pump surface and

1,5 meters above the floor, usi ng a sta ndard pre ssure reference of 0,000 02 newton pe r squa re meter.

-

Overall noi se level, dB (A) is determine d a t points of maximum noise l evel an d the values o f all

mid-ban d freq uences ar e b asis A scale readi ngs.

Whe n the requi red con dition flow is outside the ra nge of 75 to 1 25% BEP, a part loa d corre ction (PLC) must be

ad ded to the noise level a s fo llows:

Percent o f BEP @ req uired

impeller diameter

PL C in

dB

74 to 6 2 or 12 6 to 136

+1

61 to 5 0 or 13 7 to 150

+2

+3

+4

37 to 2 5

1

0 .5

0

49 to 3 8

3

2.5

2

1.5

Octave MID_BAND Frequenc y, HZ

0

1

2

4

6

9

1 0

Advertising