2 imperial units, 2 notes – Flowserve LNGT User Manual

Page 22

Advertising
background image

LNGT USER INSTRUCTIONS ENGLISH 00083107 02-08

Page 22 of 48

®

4.4.3.2 Imperial units

Maximum forces [F] in lbf and moments [M] in lbf•ft – multiply by 1000

Suction Discharge

Type and size

Fx Fy Fz Mx My Mz Fx Fy Fz Mx My Mz

150LNGT375

3.87 4.83 3.11 3.66 1.83 2.71 2.90 3.63 2.34 2.37 1.22 1.83

150LNGT400

3.87 4.83 3.11 3.66 1.83 2.71 2.90 3.63 2.34 2.37 1.22 1.83

150LNGT475

3.87 4.83 3.11 3.66 1.83 2.71 2.90 3.63 2.34 2.37 1.22 1.83

200LNGT300

4.83 6.05 3.90 5.21 2.57 3.93 3.87 4.83 3.11 3.66 1.83 2.71

200LNGT350

4.83 6.05 3.90 5.21 2.57 3.93 3.87 4.83 3.11 3.66 1.83 2.71

200LNGT400

5.81 7.26 4.68 8.46 4.13 6.36 3.87 4.83 3.11 3.66 1.83 2.71

200LNGT425

3.87 4.83 3.11 3.66 1.83 2.71 3.87 4.83 3.11 3.66 1.83 2.71

200LNGT475

4.83 6.05 3.90 5.21 2.57 3.93 3.87 4.83 3.11 3.66 1.83 2.71

200LNGT500

3.87 4.83 3.11 3.66 1.83 2.71 3.87 4.83 3.11 3.66 1.83 2.71

200LNGT550

4.83 6.05 3.90 5.21 2.57 3.93 3.87 4.83 3.11 3.66 1.83 2.71

200LNGT600

3.87 4.84 3.12 3.66 1.83 2.71 3.87 4.83 3.11 3.66 1.83 2.71

250LNGT325

4.83 6.05 3.90 5.21 2.57 3.93 4.83 6.05 3.90 5.21 2.57 3.93

250LNGT425

5.81 7.26 4.68 8.46 4.13 6.36 4.83 6.05 3.90 5.21 2.57 3.93

250LNGT500

5.81 7.26 4.68 8.46 4.13 6.36 4.83 6.05 3.90 5.21 2.57 3.93

250LNGT575

5.81 7.26 4.68 8.46 4.13 6.36 4.83 6.05 3.90 5.21 2.57 3.93

250LNGT625

5.81 7.26 4.68 8.46 4.13 6.36 4.83 6.05 3.90 5.21 2.57 3.93

300LNGT275

6.72 8.47 5.46 8.80 4.33 6.57 5.81 7.26 4.68 8.46 4.13 6.36

300LNGT300

6.72 8.47 5.46 8.80 4.33 6.57 5.81 7.26 4.68 8.46 4.13 6.36

300LNGT400

7.73 9.68 6.24 10.15 5.08 7.51 5.81 7.26 4.68 8.46 4.13 6.36

300LNGT425

7.73 9.68 6.24 10.15 5.08 7.51 5.81 7.26 4.68 8.46 4.13 6.36

300LNGT500

6.72 8.47 5.46 8.80 4.33 6.57 5.81 7.26 4.68 8.46 4.13 6.36

300LNGT725

6.72 8.47 5.46 8.80 4.33 6.57 5.81 7.26 4.68 8.46 4.13 6.36

350LNGT325

7.73 9.68 6.24 10.15 5.08 7.51 6.72 8.47 5.46 8.80 4.33 6.57

350LNGT400

9.68 12.10 7.80 12.73 6.36 9.41 6.72 8.47 5.46 8.80 4.33 6.57

350LNGT450

9.68 12.10 7.80 12.73 6.36 9.41 6.72 8.47 5.46 8.80 4.33 6.57

350LNGT525

9.68 12.10 7.80 12.73 6.36 9.41 6.72 8.47 5.46 8.80 4.33 6.57

350LNGT600

7.73 9.68 6.24 10.15 5.08 7.51 6.72 8.47 5.46 8.80 4.33 6.57

350LNGT675

9.68 12.10 7.80 12.73 6.36 9.41 6.72 8.47 5.46 8.80 4.33 6.57

400LNGT350

9.68 12.10 7.80 12.73 6.36 9.41 7.73 9.68 6.24 10.2 5.08 7.51

400LNGT550

9.68 12.10 7.80 12.73 6.36 9.41 7.73 9.68 6.24 10.2 5.08 7.51

500LNGT375

11.56 14.52 9.34 15.91 7.99 11.8 9.68 12.10 7.80 12.7 6.36 9.41

500LNGT450

11.56 14.52 9.34 15.91 7.99 11.8 9.68 12.10 7.80 12.7 6.36 9.41

500LNGT650

11.56 14.52 9.34 15.91 7.99 11.8 9.68 12.10 7.80 12.7 6.36 9.41

500LNGT800

11.56 14.52 9.34 15.91 7.99 11.8 9.68 12.10 7.80 12.7 6.36 9.41

600LNGT875

15.46 19.35 12.47 21.66 10.8 16.1 11.56 14.52 9.34 15.9 7.99 11.8

600LNGT1150

19.35 24.19 15.59 27.08 13.5 20.0 11.56 14.52 9.34 15.9 7.99 11.8

700LNGT700

19.35 24.19 15.59 27.08 13.5 20.0 13.44 16.93 10.91 19.1 9.54 14.2

900LNGT650

19.35 24.19 15.59 27.08 13.5 20.0 17.34 21.77 13.98 23.8 11.9 17.6

900LNGT1050

23.11 29.03 18.68 32.49 16.2 24.1 17.34 21.77 13.98 23.8 11.9 17.6

1000LNGT750

19.35 24.19 15.59 27.08 13.5 20.0 19.35 24.19 15.59 27.1 13.5 20.0


4.4.3.2 N

otes

1. F= External force, tensile or compression.
M= External moment, CW or CCW
2. Forces and Moments may be applied simultaneously in any direction.
3. Values apply to all materials.
4. Higher loads may be acceptable,if direction and magnitude of individual loads are known: approval needed.
5. Pumps must be on rigid foundations and baseplates.
6. Pump/Baseplate should not be used as pipe anchor. Expansion joints must be properly tied.
7. Specified pump foot bolt torque must be used. Bolt Yield Strength > 300 N/mm² [>43000 psi]
8. Sign Convention follows API 610 10th Edition / ISO 13709 and ISO 1503

Advertising