4 inspection and reconditioning – Flowserve ISC2 Single Pusher Repair User Manual

Page 3

Advertising
background image

3

Seal parts that are reconditionable

• Gland assembly [11]

• Sleeve assembly [1]

• Sleeve collar [58]

4 Inspection and Reconditioning

There are certain critical areas of each part where special attention should be

paid to the condition. If any of the listed areas show signs of wear, corrosion,

or other defects that cannot be removed without affecting the dimensional size

of the surfaces by more than 0.001 - 0.002 inch (0.025 - 0.05 mm), then the

respective part should be replaced. If grit blasting is performed, polish the O-ring

surfaces to achieve the required surface finish (see critical area listings for finish

requirements). If any parts require machining to correct damage, please contact

your Flowserve representative for dimensional requirements, or for any other

questions regarding repair.
4.1 Gland assembly [11] see Figures 2 and 3.
A Dynamic O-ring surface - Inspect for wear,

fretting, nicks, scratches or corrosion.

Required surface finish: 32 RMS

B Gasket surface - Remove the old gasket and

clean the gasket surface. Inspect for nicks,

scratches or corrosion.

C Pipe taps and lifting holes - Inspect for

damaged threads or corrosion. Re-tap as

necessary.

D Anti-rotation pins - Inspect for wear or

corrosion. Replace as necessary.

4.2 Sleeve assembly [1] see Figures 4 and 5.
A O-ring surfaces - Inspect for wear, nicks,

scratches, or corrosion. Required surface

finish: 63 RMS.

B Drive flats or drive pin - Inspect for wear or

corrosion. Replace pin as necessary.

C Drive end roundness - No greater than

0.001 inch (0.025 mm) TIR (Total Indicated

Reading) under the bushing.

D Inspect ID of sleeve at weld point for

corrosion.

Figure 2

C

D

B

A

B

A

Figure 3

C

D

Advertising