3.3 O-ring Mounted Stationary Face

3.3.1 Assemble seat gasket to stationary face (lubricate gasket with silicone base

grease only, unless otherwise specified on seal drawing) and install in gland.

Caution:

If anti-rotation pin is used, make sure stationary face is properly seated.

Do not get grease on running face.

3.3.2 Install gland gasket - Use silicone grease if necessary to retain gasket.

3.4 Clamped Stationary Face

3.4.1 Install flat gasket into gland.

3.4.2 Install stationary face into gland.

3.4.3 Install second flat gasket to stationary face.

Note: If two gasket materials are supplied, install PTFE gasket at this location.

Use silicone grease to retain gasket if necessary.

Do not get grease on running face.

3.5 Using lint free tissue, clean stationary and rotating face mating surfaces.

Alcohol or acetone can be used as a cleaning agent to assure clean, film free,

dry faces. Any other materials may cause premature seal failure.

Caution:

Consult material safety data sheets for proper handling of alcohol or acetone.

3.6 Assemble gland to seal chamber face. See Figure 2.

Caution:

During gland assembly over shaft, be sure stationary face is not damaged.

Secure bolts attaching gland to housing.

Note:

Even torque is required on all gland bolts to assure proper seal operation.

Tighten gland stud nuts evenly, cross stagger the adjustment of the nuts. Follow the

equipment manufacturer’s recommendation for gland stud nut torque. In the absence

of recommendations, gland stud nuts should only be torqued to establish a leak tight

seal at the gasket. Proper land bolt adjustment is especially important with clamp

style inserts where torque may damage the insert. In this case, gland stud nuts

should be torqued to a maximum of 13.5 N-m (10 ft-lbs).

4 Hook Sleeve Mount

For proper seal installation, you must obtain the correct seal assembly drawing

for your application.

4.1 Inspect pump shaft. Clean and remove any burrs, nicks, scratches, etc.

which could cause damage to gaskets when assembling seal.

4.2 Assemble shaft sleeve and flat gasket to pump shaft and seat in accordance

with pump manufacturer’s specifications. Inspect for and remove any burrs.

Seal Setting on Hook Sleeve Figure 3