6 piping instructions, 7 repair – Flowserve Q Series BW Seals User Manual

Page 7

Advertising
background image

7

Type 3 (setting blocks)

Figure 7

Setting Block

• Tighten drive collar set screws to shaft.

• Loosen and remove setting blocks.

6 Piping Instructions

Do not start up the equipment dry. Vent air from the casing of the pump and the seal

chamber before startup.

Refer to assembly drawing for mechanical seal piping instructions.

Note:

For special problems encountered during installation, contact your nearest

Flowserve Sales and Service Representative or Authorized Distributor.

7 Repair

This product is a precision sealing device. The design and dimension tolerances are critical

to seal performance. Only parts supplied by Flowserve should be used to repair a seal. To

order replacement parts, refer to the part code and B/M number. A spare backup seal should

be stocked to reduce repair time.
When seals are returned to Flowserve for repair, decontaminate the seal assembly and

include an order marked "Repair or Replace." A signed certificate of decontamination

must be attached. A Material Safety Data Sheet (MSDS) must be enclosed for any

product that came in contact with the seal. The seal assembly will be inspected and,

if repairable, it will be rebuilt, tested, and returned.