Figure 4, Seal, Size – Flowserve Uniseal Series BW Seals User Manual

Page 4: Torque, Figure 5

Advertising
background image

4

Figure 4

2.6 Orient the Uniseal with the ports aiming as shown on the seal assembly

drawing. See Section 3 for Piping Recommendations.

2.7 Tighten the gland nuts evenly in a diagonal sequence. Do not over-

tighten the gland nuts, as this can warp seal parts and cause leakage.

Confirm adequate thread engagement before final torque setting.

Recommended Uniseal minimum gland nut torque by size range:

Seal

mm

25 - 50

54 - 67

Size

(inch) (1.000 - 2.000) (2.125 - 2.625)

Torque

20 N-m

27 N-m

(15 ft-lbs)

(20 ft-lbs)

2.8 Assemble the equipment per manufacturer specifications. Avoid pipe

strain. Align the coupling per manufacturer specifications.

2.9 With the impeller, shaft, coupling and bearings in their final operating

position, tighten the drive collar set screws. See Figure 4.

Recommended Uniseal minimum set screw torque by size range:

Seal

mm

25 - 60

67

Size

(inch) (1.000 - 2.500)

(2.625)

Torque

4.5 N-m

13.5 N-m

(40 in-lbs)

(120 in-lbs)

2.10 Remove the setting devices from the drive collar by loosening the cap

screws. See Figure 5. Save the setting devices and fasteners for future use

when the pump impeller is reset or when the seal is removed for repairs.

2.11 Turn the shaft by hand to ensure unobstructed rotation.
2.12 See Operational Recommendations before start-up.

Figure 5

Advertising