For Plans 52 and 53:

Shaft Rotation

Inlet

Outlet

(from exposed end of gland)

Clockwise (CW)

Port b

Port a

Counterclockwise (CCW)

Port a

Port b

3.4 For dual pressurized seal (double seal) operation, supply a clean,

compatible barrier fluid at a pressure at least 1.7 bar (25 psi) above the

seal chamber pressure. See Figure 8. The pressure of the barrier fluid

must not exceed the recommended maximum pressure.

Dual pressurized (Plan 53A) Uniseal with Supply Tank

Figure 8

CW

Rotation

F

F

V

CCW

Rotation

a

b

3.3 For dual seals, follow the port

connections listed below, see Figure 7.

Uniseals are unidirectional and piping

the correct inlet and outlet is important

to proper circulation. The liquid barrier

inlet should draw from the bottom of the

support system while the liquid barrier

outlet feeds the top of the system. After

venting, plug the vent port.

6

Dual seal port connections

Figure 7

Image is not to scale