4operational recommendations – Flowserve Uniseal Series BW Seals User Manual

Page 7

Advertising
background image

7

3.5 For dual unpressurized (tandem seal) operation, supply a clean,

compatible buffer fluid at a pressure below the seal chamber pressure.

The pressure in the seal chamber must not exceed the recommended

maximum pressure.

3.6 Dual seal recommendation: For enhanced seal performance and

reduced coking, use DuraClear as a barrier fluid. Refer to DuraClear

brochure FSD123 or contact a Flowserve representative for further details.

4

Operational Recommendations

4.1 Remove lock outs on equipment and valves.
4.2 Do not start up the pump dry to check motor rotation or for any other

reason. Open valves to flood pump with product fluid. Ensure that the seal

flush or support system is operating. Vent air from the casing of the pump

and the seal chamber before start-up.

4.3 Observe the start-up. If the seal runs hot or squeals, check the seal flush

system. Do not allow the pump to run for any extended time if the seal

gets hot or squeals.

4.4 Do not exceed corrosion limits. The Uniseal is designed to resist

corrosion through proper material selection. Do not expose the Uniseal

materials of construction to products outside of their corrosion limits.

Consult Flowserve for chemical resistance recommendations.

4.5 Do not exceed pressure and speed limits established for the Uniseal.
4.6 Do not exceed the temperature limits of the Uniseal based on the

materials of construction. For dual seals using supply tanks with cooling

coils, turn on cooling water to the supply tank before start-up.

4.7 Do not start up or run the Uniseal dry. The seal chamber, pump and

support systems should be thoroughly vented before start-up. Buffer or

barrier fluid must flood the seal cavity of dual seals at all times during

operation. Process fluid must be in the seal chamber at all times during

single seal operation.