Figure 28

9

Rotating Face Installation

9.1

Lubricate the exposed surfaces
of the rotating face gasket
including the ends and the
rotating face shoulder with
silicone grease.

9.2

With the seal drive sitting on the
bench, set the rotating face on

Figure 29

it. See Figure 28.

9.3

Align the drive pin and drive slot.

9.4

Push the rotating face radially into the seal drive and then down as
the drive pin slips into the drive slot.

9.5

Repeat this procedure to install the other rotating face half.

9.6

Lubricate the exposed surfaces of each sleeve gasket including
the ends and the split joint gaskets with silicone grease.

9.7

Loosely cap screw the havles together.

9.8

Align the rotating faces and wipe clean with alcohol.

Caution: Consult material safety data sheets for proper handling of alcohol.

10

Stationary Face Installation

10.1 Lubricate the exposed surfaces of the seat gasket including the

ends and the stationary face shoulder with silicon grease.

10.2 With the gland sitting on the bench, set the stationary face on the

spring holder as shown in Figure 29.

10.3 Align the lock pin and lock pin slot.