2.4

Gland Split
Joint
Gasket
Position
The gland
split joint
gaskets
must be
positioned
as shown in
Figure 5. If
they are not,

Split Joint
Gasket

Gland

Seat Gasket

Gland Gasket

Figure 5

5

2.5

Gasket Chamfers - The seat gasket, rotating face gasket, and
sleeve gasket are all chamfered on one side and must be
positioned as shown in Figure 6.

Figure 6

Rotating Face
Gasket
Chamfer Side

Seal Drive

Sleeve Gasket
Chamfer Side

Gland

Split Joint Gasket

Split
Joint
Gasket

Seat Gasket
Chamfer Side

2.3

Seal Drive Split
Joint Gasket
Position
The split joint
gaskets should be
positioned flush
with the groove
surfaces indicated
in Figure 4. The
gasket end should
be flush to 0.030
inch (0.76 mm)
shorter than the
groove as shown.

Flush

Flush

Flush

Split Joint Gasket

Figure 4

0.030"
0.000"

(0.76 -
0.00 mm)

reposition them as needed.