Mixerpac 2564 - Installation and Maintenance Instruction for Machinery Parts

9.7

!

Follow the instructions for recommissioning of the machine, after a machine
breakdown, see items 8.0 to 8.8.

10.0 System Check

System check of the MIXERPAC may take place during machine breakdown only.

Ensure accessibility for the necessary range to operate the machine or for main-

tenance work at the MIXERPAC.

10.1 System checks of the MIXERPAC extend to the monitoring of the set values for pres-

sure, temperature and barrier or quench fluid consumption.

10.2 Removing the MIXERPAC for an inspection becomes necessary when:

• The specified leakage values are exceeded and, after enquiries at FLOWSERVE,

no other written agreement ensues.

!

Examination of the leakage rates should take place at least once during

24 operating hours!

• After an installation period of more than three years.
• An inspection of the mixer is due, and a similarly long operating period is

expected thereafter.

10.3 The bearing is relubricated with the following quantity of grease:

Shaft-ø

(mm)

Grease quantity

(g)

Shaft-ø

(mm)

Grease quantity

(g)

40

10

140

55

50

15

160

70

60

20

180

100

80

25

200

100

100

35

220

110

120

40

Place the grease gun on the panhead grease nipple and refill according to the table.
Remove any excess grease on the upper shaft seal ring at the atmospheric side.
Recommended relubrication period approx. 1500-2000 operating hours, yet no later
than every three months. Lithium soap grease, e.g. , MOBIL Mobilux ® EP2 should
be used as the lubricant.

!

Do not mix grease with other greases or oils.