Split Mechanical Seal MSS - Installation and maintenance instructions for machinery parts

!

Tools needed for installation:

- A 5/3“ T-handle or right angle Allen wrench.
- An open end wrench for the gland bolts.
- Two () 1/8“ Allen wrenches.

!

Cleanliness during installation is crucial to the satisfactory operation of the MSS
seal.

!

Installation of this seal requires the use of an adhesive to bond the O-ring
secondary seals together. Do not allow the adhesive to come in contact with the
skin.

There are two basic models of the MSS seal, piloted, see Figure , page 9, and
NON-Piloted, see Figure 3, page 13.

Seal chamber requirements

Figure 1

!

- Bearings must be in good condition.

- Maximum axial movement of shaft (end play) = 0.010inch (0.5 mm) FIM.

- Maximun combined shaft eccentricity and shaft deflection at face of housing

total = 0.150 inch (3.8 mm) FIM.

Shaft or sleeve O.D.

±0.001” (0.05 mm)

Face of seal housing to be square to

the axis of the shaft within 0.00”

(0.5 mm) FIM. and have a 63 µinch

(Ra 1.6 µm) finish or better.

Shaft or sleeve fin-

ish to be 3 µinch

(Ra 0.8 µm) finish

or better

A

J

B

Advertising