Install tarsex bushing, Install pump seal chamber, Position gland inlet – Flowserve Dual Gas Barrier Seals User Manual

Page 4

Advertising
background image

4

2.1.1 Optional: TARSEx Bushing

Installation

• Slide seal assembly

against the bearing frame.

• Clean lubrication off pump

shaft.

• Install the friction drive

TARSEx bushing with

O-ring, positioning them

against the retaining

plate with the bushing

grooves oriented toward

the seal. See Figure 3.

Install TARSEx Bushing

(optional)

Figure 3

2.2 Install the pump seal chamber, Figure 4. Postion the seal gland

gas barrier inlet, port

A

shown in Figure 5, in the 9:00 o’clock

position and the plugged gas barrier outlet, port

B

in the 6:00

o’clock position for normal installations. Alternate positioning of the

gland may be necessary with

Install pump seal chamber

Figure 4

gland

retaining plate bushing O-ring

some pumps, where the bear-

ing housing interferes with

piping. Bolt the seal cham-

ber in place on the bearing

housing.

Note: Either port can be used for

gas barrier inlet or outlet.

2.3 Assemble the pump, adjust

the bearings, set the impel-

ler, connect pump piping.

Allow no pipe strain on the

pump casing. Connect the

Position gland inlet

Figure

Normal Installation Alternate Installation

coupling so that the shaft is in its operating axial position.

A

B

A

B

Gas

Barrier

Inlet

Port

Gas Barrier

Outlet Port

Gas Barrier

Outlet Port

Gas

Barrier

Inlet

Port

Advertising