4 Operation

To assure reliable, long-life operation of your Dual Gas Barrier Seal,

the following guidelines should be observed.
4.1 Do not exceed corrosion limits. Your Flowserve seal is designed

to resist corrosion by most chemicals. However, do not expose

the seal materials of construction to products outside of their

corrosion limits. The seal assembly drawing lists the materials of

construction. Consult Flowserve for chemical resistance ratings.

4.2 Do not exceed the pressure limits of the seal design. Do not let

the barrier gas pressure fall below 2 bar (25 psi) above the seal

chamber pressure.

4.3 Do not exceed the maximum temperature limits of the seal

design.

4.4 Do not operate at speeds lower than the seal's minimum speed,

if applicable.

4.4.1 On startup and shutdown, the seal's speed should be

transitioned between stationary and the seal's minimum

speed as quickly as possible.

4.5 For uni-directional designs, do not turn the shaft opposite to the

direction arrow indicated on the gland.

4.6 Observe the start-up. The seal barrier cavity must be pressur-

ized before pump start-up and at all times during pump operation.

For best performance, do not cavitate or run the pump dry. Open

valves to flood pump with product fluid before start-up. Maintain

the seal barrier gas pressure even when the pump is not running.

5

Reset pump impeller

To reset the pump impeller, follow plant safety procedures, etc., see 1.1.

• Reinstall the setting devices.

• Loosen the cartridge drive collar set screws.

• Adjust the impeller clearance following pump manufacturer’s

instructions.

• Tighten the set screws on the cartridge drive collar.

• Remove the setting devices. Save the setting devices and

screws.

• Perform steps 2.7 to 2.9.