2 cartridge seal installation – Flowserve Cartridge Seals User Manual

Page 3

Advertising
background image

3

1.5 Check assembly drawing included with the cartridge seal for specific

seal design, materials of construction, dimensions, and piping

connections.

1.6 Check shaft or sleeve OD, seal housing bore, and distance to

the first obstruction to ensure they are dimensionally the same as

shown on the seal assembly drawing.

1.7 Check gland pilot and bolt holes to ensure they are adaptable to the

equipment and are the same as shown on the assembly drawing.

Many cartridge seal designs include setting devices that center the

seal around the shaft and do not require a gland pilot.

1.8 Handle all seal parts with care, they are manufactured to precise

tolerances. The rubbing contact faces of the rotating and stationary

faces are of special importance. These two sealing faces are lapped

flat to within three light bands (34.8 millionths of an inch).

Keep the seal faces perfectly clean at all times.

2 Cartridge Seal Installation

2.1 Lubricate the shaft or sleeve lightly with lubricant provided with

the seal.

2.2 Install the complete cartridge seal assembly on the shaft.
2.3 For overhung pumps: Position the seal close to the bearing housing

with the seal oriented toward the pump. Install the pump back-plate

or seal housing and assemble the pump.

2.4 Position the cartridge gland against the seal housing face and

tighten the gland stud nuts up evenly, cross staggering the

adjustment of the nuts. The gland nuts should be torqued to a

maximum of 13 N-m (10 ft-lbs). Excessive gland nut pressure can

result in distortion of the stationary face.

2.5 For between bearings pumps: Assemble the bearings, coupling,

etc. and adjust the impeller so that the shaft is in its operating axial

position.

2.6 For end suction pumps: Adjust the bearings, coupling, and impeller

so that the shaft is in its operating axial position.

2.7 Tighten the set screws on the seal cartridge drive collar.
Note Any subsequent axial adjustment of the shaft requires resetting of

the seal.

Advertising