Flowserve Cartridge Seals User Manual

Page 4

Advertising
background image

4

2.8 Disengage or remove setting devices. Eccentric washer or slotted

plate type setting devices should be repositioned clear of rotating

parts and locked to the gland in a neutral position. Centering type

devices cap screwed to the sleeve drive collar should be removed

and stored for future seal removal and repair. All setting device

types need to be reinstalled for resetting the seal when repositioning

the pump impeller.

2.9 See Operational Recommendations, paragraph 3 and 4, before

starting pump.

3 Operational Recommendations for Single

Cartridge Seal

3.1 Do not start up the equipment dry. Vent air from the casing of

the pump and the seal chamber before startup. Check the seal

assembly drawing for the recommended piping plan and follow any

special instructions. Plan 11 is a good default flush plan if none are

specified for horizontal pumps.

3.2 If the seal runs hot, check for proper seal setting, seal housing

dimensions, and check the bypass or flush line for obstructions.

Do not allow the equipment to run for any extended time if the seal

gets hot or squeals.