4 Operational Recommendations for Dual

Cartridge Seal

4.1 A dual seal must be supplied a clean buffer/barrier fluid compatible

with the product.

4.2 Dual pressurized seals must at all times maintain barrier fluid

pressure at least 172 kPa (25 psig) above the maximum product

pressure in the seal chamber.

4.2 The recommended piping for a dual pressurized seal with the use

of a Supply Tank is shown in Figure 2, Plan 53A. Circulation from

an external source is shown in Figure 3, Plan 54. Other mechanical

seal support systems are also available from Flowserve.

4.3 Turn on any cooling water to the supply tank or other support

system.

4.4 Start-up the seal barrier fluid system before starting pump.
4.5 Do not start up the equipment dry. Vent air from the casing of the

pump before startup.

4.6 If the seal runs hot, check for proper seal setting, seal housing

dimensions, and check the barrier fluid system. Do not allow the

equipment to run for any extended time if the seal gets hot or

squeals.

For special problems encountered during installation, contact your

nearest Flowserve Sales and Service Representative or Flowserve