EDWARD UNIVALVE USER INSTRUCTIONS ENGLISH 12-13

14

REASSEMBLY OF UNWELDED BONNET UNIVALVES
GENERAL:
Be sure all parts are clean of dirt, rust or scale.

• Always install a new stem-disk assembly into the bonnet

if the one is damaged, e.g., the disk seat damaged or

stem scratched, worn or pitted. Make sure all dirt is

removed from old stems.

• Apply a light coating of a good high-temperature

lubricant to the bonnet-body threads, such as Bostik

Never-Seez™ – Regular Grade; stainless Univalves

should use Nickel Special Nuclear Grade. Do not use

excessive amounts, and keep it off the gasket seal faces

of unwelded Univalves.

• Next, install a new graphitic gasket seal ring – it should

always be replaced – by slipping it onto the bonnet and

placing it snugly against the off-set. A light film of oil (not

Never-Seez™) helps hold it in place.

• Slip the locking collar over the bonnet from the body end,

with the lug toward the body. Install the capscrew and

nut on the collar, but do not tighten.*

• Next carefully screw the bonnet and stem-disk assembly

into the body, making certain the disk is off the body

seat (valve is open). Using the Bonnet Torquing Collar

assembly, tighten the threads to the torque shown for

unwelded bonnet Univalves.

THIS IS VERY IMPORTANT FOR UNWELDED BONNET

UNIVALVES.

• Verify that the bonnet shoulder does not bottom out on

the body.

• Rotate the locking collar counterclockwise so the lug is

against one of the body lugs. Tighten nut to the torque

value for the yoke bolts, as shown in the next column.

• Install the packing if the original is to be replaced. See

“Packing Installation,” pg. 16.

• Making sure the stem is clean, apply a light coat of

extreme pressure grease, such as American Oil Rycon

EP-2 or equivalent on the threads. Screw the yoke onto

the stem, then onto the bonnet, turning it down snugly

against the bonnet shoulder. Lubricate and then tighten

the yoke bolt as follows:

3/8 dia. bolt

16/20 ft-lb

25/30 N-M

7/16 dia. bolt 30/35 ft-lb

45/50 N-M

• Tighten the gland bolts. IMPORTANT: per “Torque Range

for Packing Gland Bolts,” pg. 17.

• Install the handwheel or actuator. For safety reasons,

make sure the self-locking stem nut is tight on the

handwheel valves.

NOTE: Univalves with “B” prefix or no prefix have a different

type of locking collar which is installed after the bonnet has

been tightened into the body.

REASSEMBLY OF WELDED BONNET UNIVALVES
GENERAL:
Be sure all parts are clean of dirt, rust or scale.

• Always install a new stem-disk assembly into the bonnet

if the old one is damaged, e.g., the disk seat is damaged

or stem scratched/worn or pitted. Make sure all dirt is

removed from old stems.

• Class 4500 welded bonnet Univalves (only) should have

both the bonnet insert and graphitic gasket seal ring

replaced. Do this by removing the stem-disk assembly

from the bonnet, placing the new bonnet insert and

graphitic gasket seal ring over the stem, then installing

the stem back into the bonnet.

• Apply a light coating of a good high-temperature

lubricant to the bonnet-body threads, such as Bostik

Never-Seez™ Regular Grade; stainless Univalves should

use Nickel Special Nuclear Grade. Do not use excessive

amounts.

• Next, carefully screw the bonnet and stem-disk assembly

into the body, making certain the disk is off the body seat

(valve is open). Apply a nominal torque, as specified on

pg. 16 for welded bonnet Univalves.

• Seal weld the bonnet; refer to pg. 18.
• Install the packing if the original is to be replaced. See

“Packing Installation,”

pg. 16.

• Making sure the stem is clean, apply a light coat of

extreme pressure grease, such as American Oil Rycon

EP-2 or equivalent, on the threads. Screw the yoke onto

the stem, then onto the bonnet, turning it down snugly

against the bonnet shoulder. Lubricate and then tighten

the yoke bolt as follows:

3/8 dia. bolt

16/20 ft-lb

25/30 N-M

7/16 dia. bolt 30/35 ft-lb

45/50 N-M

• Tighten the gland bolts. IMPORTANT: per “Torque Range

for Packing Gland Bolts,” pg. 17.

• Install the handwheel or actuator. For safety reasons,

make sure the

self-locking

stem nut is tight

on handwheel

valves.

REASSEMBLY OF THE UNIVALVE