1.1.4 Disassembly of LB Subassembly

Step 1

Loosen the two clamps (#7) that secure the bellows boot in place on the anti-rotation base (#1) and shaft (#2). Slide
both clamps over the bellows boot and remove.

Step 2

Remove the bellows boot (#7) by turning and pulling off of the anti-rotation base (#1).

Step 3

Remove shaft (#2) by pulling shaft out through the bottom of the anti-rotation base (#1), as shown in Figure 1.4.

NOTE: Steps 4 and 5 are for the LB2 assembly only. The LB2 anti-rotation base consists of three parts: the base (#1),
the nut (#14) and the O-ring (#15).

Step 4

LB2 assembly only.
Remove the anti-rotation nut (#14) by pushing the nut from the bottom side of the anti-rotation base then removing
from the top side.

Step 5

LB2 assembly only.
Remove O-ring (#15) from anti-rotation nut (#14).

Figure 1.4 – LB Assembly
LB2 assembly shown in this figure.