Flowserve TX2 Triple Offset High Performance Butterfly Valve IOM User Manual

Page 10

Advertising
background image

Flow Control Division

10























11.5 Install the gland follower and tighten it to firmly seat the packing. DO NOT compress the gland follower too
much. Over-tightening may dramatically reduce the life of the packing and may make it more difficult to operate the
valve. The maximum torque of the gland screw as below,

Graphite Packing

Screw Size

Max. Torque

M8

110

Kg-cm

M10

120

Kg-cm

M12

140

Kg-cm

M16

450

Kg-cm

M20

650

Kg-cm

11.4

Install each new ring of packing, use the gland

follower to push each ring of packing evenly into
position after starting it in the stuffing box bore.
Stagger the splice-joints of each packing ring so they
are as far as possible from each other (see example
above). Usually, rotating each ring until the splice is
at 90°

from the previous splice is sufficient. (Fig.14)

Fig 14