SECTION IX

REMOVAL PROCEDURE

To remove your valve from the pipeline, please follow these simple steps:
Ensure that the valve is in the closed position.
Ensure that the line is depressurized.
Use protective clothing and equipment to prevent injury.
If your valve is equipped with a fail-open actuator, manually close the valve or disconnect the actuator then close
the valve before removal.
Attach nylon slings to the body shoulders of the valve and around the body of the actuator.
Remove the bolts holding the valve to the pipeline flanges.

SECTION X

LUBRICATION SCHEDULE

Flowserverecommends that your valve be inspected at least every three months to determine lubrication and other
maintenance requirements dependign upon your specific service conditions.

SECTION XI

STUFFING BOX MAINTENANCE PROCEDURE

Routine maintenance of the stuffing box consists of tightening the packing gland periodically. If leakage around the
stuffing box is discovered, first tighten the hex-nuts on the gland follower (more than 2/3 compression) as this may
reduce packing life. If the leakage still persists, replace the packing according to the following procedure. (For
clarity, the actuator and bracket are not shown in the following diagrams. It is not necessary to remove the actuator
or bracket before performing this procedure).
11.1 In order to gain access to the packing, remove the gland follower and slide it up to the actuator. See the diagram
below:









Fig 10

Advertising