- 11 -






6.4 Assembly component “Plug”

Fig. 3


• Fixation of the plug (2.2)


• Screw the stem (2.4) into the plug (2.2)


• Drill both plug (2.2) and stem (2.4)

together


• Press the spring pin (2.3) into the

drilled hole


After pressing in the dowel pin, the plug
and stem must be aligned to one another !

• Insert the fuse carrier (2.14) in the plug

(2.2)


• Put the piston sleeve (2,13) onto the

plug (2.2)


• Screw the lock nut (2.25) onto the plug

(2.2) (for tightening torques, see page
9)


• The lock nut (2.25) must be secured by

welding spots against automatic
loosening !