5. Repair
If a fault or defect occurs which, according to the list of measures before, requires the customer
services departement or contract partner to be contacted, the manufacturer`s guarantee shall
be rendered null and void - and the manufacturer released from any responsibility - unless the
customer services department or contract partner is duly notified.
Service hotline Austria:
+43 (0)664 341 8 616
6. Assembly
These procedure assumes that the Injection Nozzle Valve is completely disassembled. If it is
not, start the instructions at the appropriate step.
6.1 Cleaning
Carefully clean all valve parts before beginning assembly!
6.2 Lubrication
Lightly grease all guide pieces
For lubricant to be used, see table 1
LUBRICANT
Klüber Wolfracoat C – Item no.: 089032
Tab.: 1
Lightly grease all screw threads
For lubricant to be used, see table 2
LUBRICANT
Klüber Wolfracoat C – Item no.: 089032
Tab.: 2