Defect

No.

Possible cause

Remedy


Excessive valve seat leakage

4.1


4.2


4.3


•

damaged sealing edges at
valve seat or plug

•

foreign particles in seat area


•

plug does not close fully

•

contact customer services
department or contract partner

•

contact customer services
department or contract partner

•

refer to 3.1 to 3.5


Leaking stuffing box system

5.1




5.2








5.3


5.4


•

compression force on packing
too low



•

worn packing








•

dirty spindle


•

damaged spindle

•

slightly re-tighten stuffing box packing

Caution: make sure the valve spindles
can still move !

•

slightly re-tighten stuffing box packing

Caution: make sure the valve spindles
can still move !

•

if the packing does not stop leaking,
contact customer service department
or contract partner

•

clean spindle with suitable cleaning
agent

•

contact customer services
department or contract partner


Leaking top or lid seal

6.1


6.2

•

pressing force on seal(s) too
low

•

seal(s) defective

•

properly re-tighten top or lid nuts
crosswise

•

contact customer services
department or

contract partner


Leaking housing

7.1


•

medium or flow related damage

•

contact customer service department
or

contract partner


No limit switch signal

8.1


8.2

•

power supply to limit switch
interrupted

•

limit switch misadjusted

•

check power supply ( voltage, circuit
breakers, connections )

•

readjust limit switch; operating
distance see limit switch data sheet


Vibrating positioner

9.1

•

defective positioner

•

see maintenance and operating in
structions of positioner manufacturer


If the problem is not solved by taking the above measures, contact the customer services
department or contract partner.