background image

13

Limitorque

®

L120-190 through L120-2000 FCD LMENIM1203-00 – 10/11

flowserve.com

5.3.1 Mounting Base

The mounting hole sizes and quantities are as detailed in Table 5.1, below:

Table 5.1 – Mounting Base Dimensions

Actuator Size

Mounting Holes

Tap Size

ISO

Bolt Circle

ISO

Quantity

MSS

MSS

L120-190

8

3/4–10 x 1.13

M20 x 2.5 x 32

11.75

298 mm

L120-420

8

7

⁄

8

–9 x 1.75

N/A

14.0

N/A

L120-800 (Torque Only)

8

3/4–10 x 1.63

N/A

17.0

N/A

L120-800 (Thrust Only)

8

1.25–7 x 2.0

N/A

16

N/A

L120-2000 (Torque Only)

16

1–8 x 2.0

N/A

23.5

N/A

L120-2000 (Thrust Only)

12

1-1/2–6 x 3.0

N/A

18.0

N/A

5.3.2 Stem Acceptance

The maximum stem acceptance is provided in Table 5.2, below:

Table 5.2 – Maximum Stem Acceptance

Actuator size

Drive 2 Tapped

Drive 1 Bore

Drive 1 Key

inch

mm

inch

mm

inch

mm

L120-190

3.5

89

2.875

73

3/4 x 1/4

20 x 12

L120-420

5

127

4.25

108

1 x 3/4

28 x 16

L120-800

5

127

7

178

1 x 3/4

32 x 18

L120-2000

6.25

159

8.00

203

11/4 x

7

⁄

8

40 x 22

NOTE: For complete mounting dimensions, see sales brochure LMENBR1200.

5.4 Double Torque Switch

The torque switch is designed to protect the actuator in open and close directions.

Figure 5.1 – Double Torque Switch

NOTE: See Caution and Note on following page.

OPEN