8 Electrical Requirements

Table 2 represents approximate current draw (at rated stall torque) in
amperes at various voltages for each motor.

Actual values depend on several variables. For exact values, test the
unit at a particular load.

Table 2: Approximate Current Draw (amps)

Suffix

Code

Duty

Cycle

Voltage

Actuator Size

10

12

15

20

22

23

Blank

20%

120 AC

0.7

Blank

25%

120 AC

0.7

0.7

1.5

1.5

2

10%

120 AC

1.5

1.5

2.9

2.9

4

75%

120 AC

0.3

0.3

0.7

0.7

0.7

5

100%

120 AC

0.25

0.25

0.5

Blank

25%

240 AC

0.4

0.4

0.9

0.9

2

10%

240 AC

0.6

0.6

1.3

1.3

4

75%

240 AC

0.15

0.15

0.3

0.3

0.3

5

100%

240 AC

Table 3: Cycle Time (Sec.)

Actuator Size

Suffix

Code

10

12

15

20

22

23

Blank

5

8

5

5

8

2

2.5

4

2.5

4

4

17, 15

27, 25

17, 15

27, 25

25

5

17

27

27

9 Illustrations

9.1 DeviceNet Board Assembly Installation

Table 4

Item

Qty

Description

1

1

DeviceNet Circuit Board

2

2

6-32 Socket Head Cap Screw (1.00")

3

2

Hex Spacers (.50")

4

1

4-40 Round Head Screw (1.50")

5

2

6 Lockwasher

6

2

6-32 Round Head Screw (.25")

7

3

4-40 Round Head Screws (.38")

8

1

Relay Board

9

1

Round Head Screw (1.00") – Reused from switch

mounting

Figure 3: DeviceNet Board Assembly

� ��

������������������

����������������