– 11 –

Limit switches cams must be adjusted separately with valve in an open and
closed position. With the valve in fully open or closed position adjust the
lower cam 3 to desired position by rotating it with special tool F5-22 or by the
tip of a screw driver placed in one of the slotted holes on the cam. Stroke the
valve fully and repeat the procedure above to set the upper cam.
Stroke valve open/closed to check proper limit switch operation.

Switches & Sensors

Technical specifications

General
Conduit entries

2x 1/2 NPT or 2x PG 13,5 (M20)

Housing material

Die cast aluminum

Surface treatment

ED painting

Mounting

According to VDI/VDE 3845

Fasteners

Stainless steel A2/A4

Terminals

2,5 mm

2

(AVG 14)

Enclosure

IP66, NEMA 4

Switches, mechanical
Type

Mechanical SPDT V3

Rating

*6/2,5A 250 VAC *Res/Ind

Approvals

CSA,UL,VDE

Temp range

-20

°

C to 80

°

C (-4

°

F to 185

°

F)

Sensors, Namur
Type

Proximity DIN 19234 NAMUR

Load Current

1mA

3mA

Voltage range

5-25 VDC

Hysteresis

0,2%

Temp range

-20

°

C to 80

°

C (-4

°

F to 185

°

F)

Potentiometer
Out put

5k

(4k

at 90

°

)

Elements

Conductive plastic

Power rating at 70

°

1 W

Linearity

1%

Resolution

Essentially infinite

Temp range

-20

°

C to 80

°

C (-4

°

F to 185

°

F)

4-20 mA position transmitter
Power supply

9-28 VDC (24VDC recommended)

Out put signal

4-20 mA

LED indication at 4 mA

±

1%

LED indication at 20 mA

±

1%

Resolution

Infinite

Minimum rotation travel

30

°

Maximum rotation travel

90

°

Linearity

<1% of full scale

Hysteresis

<0,5% of full scale

Out put current limit

24 mA DC

Load impedance

800

at 24 VDC

Temp range

-20

°

C to 80

°

C (-4

°

F to 185

°

F)

NAMUR switches

2
3

5
6

Upper
switch

Lower
switch

+
-

+
-

1
2
3

6
5
4

Upper
switch

Lower
switch

C

C

Mechanical switches

NC

NC

NO

NO

1
2
3

6
5
4

Upper
switch

Lower
switch

C

C

Mechanical switches

NC

NC

NO

NO

Weight
Standard enclosure

0.7 kg (lbs 1.5)

Explosion proof

2.1 kg (lbs 4.6)

Switches proximity
Contact rating

2 W or 2 VA @ 30 VDC/
VAC, 0.1 A

Maximum operating time

0.5 miliseconds

Breakdown voltage

200VDC

Contact resistance

0.2 Ohms

Switch type

SPDT hermetically sealed
in one unit

Mechanical and
electrical life

>10 million operations

Proximity switches