System malfunctions – Flowserve NRR 2-40 User Manual

Page 25

Advertising
background image

25

LED “Bus status” flashes slowly.

Fault:

Data transfer in CAN bus interrupted.

Remedy: The bus cables have to be correctly connected according to the wiring

diagram (observe polarity!). Make sure that all end-of-line devices are
provided with 120

terminating resistors, see wiring diagram.

Disconnect the system from its power supply. After 5 sec. apply power
and restart system.

Fault:

Malfunction in CAN bus.

Remedy: Restart system.

Fault:

The baud rate of one or more bus-based devices is not set correctly.

Remedy: Check baud rate settings of all bus devices. The baud rates must be

identical. Refer to section “Annex” for more details.

Disconnect the system from its power supply. After 5 sec. apply power
and restart system.

Fault

The overall length of the bus cable does not correspond to the selected
baud rate.

Remedy: Change baud rate settings of all bus-based devices according to the

indications specified in “Annex”.
Disconnect the system from its power supply. After 5 sec. apply power
and restart system.

LED “Bus status” flashes slowly.

High/low-level alarm

System malfunction 3

System Malfunctions

– continued –

LED flashes slowly

LED flashes slowly