Important Notes

Safety Note

Danger

When loosening the electrode steam or hot water might escape.
This presents the danger of severe injuries to the whole body. It is
therefore essential not to remove the electrode unless the boiler pressure
is verified to be zero.
The electrode is hot during operation.
This presents the danger of severe burns to hands and arms.
Installation and maintenance work should only be carried out when the
system is cold.

The equipment must only be installed by qualified staff.

Qualified staff are those persons who – through adequate training in electrical
engineering, the use and application of safety equipment in accordance with
regulations concerning electrical safety systems, and first aid & accident
prevention – have achieved a recognised level of competence appropriate to the
installation and commissioning of this device.

Usage for the intended purpose

Use level electrodes type NRG 16-38 S, NRG 16-39 S only in conjunction with
controller type NRS 1-7 for high-liquid level limiting (M

AX

. level alarm) and level

monitoring in marine steam boilers and (pressurized) hot water installations.

Classification pursuant to article 1 PED *)

Category

none

Designation

Safety accessory

CE marking

no

*) PED = Pressure Equipment Directive